Specifications | ||
AC Current range | 42.00 to 1000 A AC, 3 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), Average rectifier effective value | |
AC Voltage range | 4.200 to 600 V AC, 4 ranges (±2.3 % rdg. ±8 dgt. at 50 or 60Hz), Average rectifier effective value | |
DC Voltage range | 420.0 mV to 600 V DC, 5 ranges (±1.3 % rdg. ±4 dgt.) | |
Other functions | Resistance: 420.0 to 42.00 M-ohm, 6 ranges, Accuracy: ±2.0 % rdg. ±4 dgt. (at 420 to 420 k-ohm range), Continuity: 420.0 ohm (Buzzer sounds at approx. 50 ohm or less) | |
Frequency characteristics | (at AC current / voltage) AC current: 50/60 Hz, AC voltage: 50 to 500 Hz | |
Display section | Digital / LCD, maximum 4199 dgt. | |
Sampling rate | 2.5 times/sec or 1 times/3 sec | |
Max. circuit voltage | 600 V AC rms (insulated wire) | |
Power supply | CR2032 (3 VDC) × 1, Continuous use 150 hours | |
Core jaw diameter | Ø 33 mm(1.30 in) | |
Dimensions | 57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (22.44 oz) | |
Accessories Included | TEST LEAD 9208 (1), CARRYING CASE 9398 (1) | |
General Specifications | ||
LCD panel | 4199 maximum display value | |
Out of range indication | OF or -OF | |
Battery low warning | (during which time accuracy cannot be guaranteed). | |
Data hold indication | ||
Zero suppression | 5 count or less (current measurement only) | |
Display update interval | FAST: 400 ms ±25 ms, SLOW: 3.2 s ±0.2 s | |
Range switching | Auto range / Manual range | |
Withstand voltage | Between case and circuit: AC4290 Vrms for 1 min. Between clamp sensor and case: AC7060 Vrms for 1 min. Between clamp sensor and circuit: AC5400 Vrms for 1 min. | |
Location of use | Altitude up to 2000 m (6562 feet), indoors, Pollution Degree 2 | |
Maximum conductor diameter for measurement | φ33 mm (1.30") or less | |
Operating temperature and humidity | 0 to 40°C (32 to 104°F), 80%RH max (no condensation) | |
Storage temperature | -10 to 50°C (14 to 122°F) (no condensation) | |
Temperature characteristics | In 0 to 40°C (32 to 104°F) range: 0.1 x Measurement accuracy / (°C) | |
Power supply | Lithium battery: CR2032 x 1 (Rated supply voltage 3 V DC) | |
Maximum rated power | 15 mVA | |
Continuous operating time | Approx. 150 hours (standard), Approx. 80 hours min. (in AC current measurement mode, continuous, no load) | |
Dimensions and mass | Approx. 57W x 175H x 16D mm, approx. 100 g (Approx. 2.24"W x 6.89"H x 0.63"D, approx. 3.5 oz.) | |
Drop proof | One meter to concrete | |
Accessories | Instruction manual, 9398 Carrying Case, L9208 Test Leads | |
Maximum rated voltage to earth | Current measurement section: Measurement category CAT III 600 V (anticipated transient overvoltage 6000 V) Voltage measurement section: Measurement Category CAT III 300 V, CAT II 600 V (anticipated transient overvoltage 4000 V) | |
Applicable standards | Safety :EN61010 EMC :EN61326 |
No |
1000 A |
600 V |
600 V |
Yes |
1.75 IN |
9.00 IN |
3.50 IN |
9030310000 |
3A992 |
Japan |
1.75 IN |
9.00 IN |
3.50 IN |