Product Details
Product Description
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
GE IC660ELB912
egradation, use a separate metal conduit run for both the sensor and signal/power wiring. Transmitter power passes through the signal leads. Under ideal conditions, the use of conduit and shielded wire may not be required. However, to avoid noise problems, enclose the sensor and signal/power wiring in separate conduit. Just prior to entering the housing, terminate rigid conduit and install a short length of flexible conduit to reduce any stress to the housing. Signal/power wiring must bear a suitable voltage rating, a temperature rating of 75-degrees Celsius (167-degrees Fahrenheit), and must be in accordance with all NEC requirements for the installation site. OTHER EQUIPMENT INTERFACE The transmitter has an isolated output and controls the loop current between four and 20 milliamperes depending on the range and PV values. Since the output is isolated, the instrument loop may have a maximum of one nonisolated device within its circuit. The maximum load on the current loop must not exceed the values shown in Figure 1-1. TRANSMITTER ROTATION The transmitter has four pairs of threaded mounting holes. Since these holes are located at the corners of the transmitter, it can be mounted in any of the four positions as shown in Figure 3-2. INSTALLATION SEQUENCE Refer to Figure 3-3 for the transmitter installation sequence. Each block of the flow represents a single task that must be completed before continuing with the sequence. In some cases, more than one path can be taken during installation. For paths that are in parallel, either complete all of the tasks in all of the paths before continuing or complete all of the tasks in only those paths that apply before continuing. At least one path must be completed. Some blocks contain alphanumeric codes. These codes identify the procedure that describes the steps to complete an INSTALLATION INSTALLATION SEQUENCE 3 - 4 WTPEEUI520002A1 indicated task. Complete all of the steps given in a procedure before continuing to the next procedure. The procedures have check boxes in the margin by each procedural step. When performing a procedure, check each box as each step is completed. By treating each task as a separate entity, the procedures provide an easy method for finding the information needed to perform each task in the installation sequence. Figure 3-2. Transmitter Rotation N O R OTAT IO N 90 R OTAT IO N o 2 70 R OTAT IO N o 180 R OTAT IO N o T03432A Figure 3-3. Installation Sequence TR4027A MOUNTING SCHEME? S TA RT HINGE WALL PA N E L PIPE DONE WIRING AND GROUNDING WALL PR5 MOUNTING PIPE MOUNTING HINGE MOUNTING PA N E L MOUNTING PR3 PR1 PR4 PR2 INTRODUCTION WTPEEUI520002A1 4 - 1 SECTION 4 - OPERATING PROCEDURES INTRODUCTION The Type TB82TE transmitter has six main operating modes: measure, calibrate, output/hold, configure, security, and secondary display. An operating mode has several programming states that contain functions specific to that mode. The transmitter has a built-in user interface through which all transmitter functions are programmed or monitored. In order to maximize the viewing area and minimize the space needed for the keypad, the patent-pending interface uses a custom LCD and four-button keypad. Instrument functions and programming prompts are available through two regions on the LCD. These regions include a primary area that shows the PV (conductivity) and a secondary area that displays text prompts for programming or auxiliary information. In addition to the user friendly interface, the transmitter has a group of icons that alert the user of an existing fault condition, diagnostic spike output, or a held output. These icons, located at the top of the LCD, only appear under the specified condition. Pressing the FAULT info smart key while in the measure mode allows interrogation of any fault condition.
>>
Compatible Duplicator Rz Ink Cartridge
>>
787mm Small Toilet Paper Machine Price Waste Paper Recycling Machine Toilet Tissue Paper Making Machine
>>
Drilling Machine H Beam Drilling Machine Yswz1000
>>
Hot Fashion Genuine Leather Reversible Black Rotate Buckle Double Sided for Men
>>
Industrial Large Volume Rectangular Stainless Steel Drinking Water Storage Tank
>>
Medical Es101 Sensor 3.9mm 10-100mm Dof Endoscopy Camera Module
>>
luxury houses front high arched double glass transom design waterproof privacy best security metal wrought iron doors for homes
>>
Ceiling tiles decorative mesh plate metal aluminum mesh ceiling tiles
>>
33cm Red Bauble Wreaths Christmas Ball with Plastic Base Front Door Hanging Decoration Xmas Festival Party Decor
>>
MAICTOP GOOD QUALITY BODY PARTS GRILLE FOR HIACE 2014 USA 1880
>>
Haiqintop New Designed (HQ4.0) with CE Concrete Mixer Cm400
>>
62cc Shiwn Agricultural Mini Gasoline Garden Power Tiller
>>
FEILONG Windows And Doors aluminum patio door double glass glass sliding doors
>>
Hot Sale Nestable One Way Shipping Single Use Export Recycle 9 Feet Euro Plastic Pallets Manufacturer 1200X1000mm/1200X1100mm/1200X1200mm/1250X1000mm Pallets
>>
Force Transfer Verification Apparatus/High Accuracy 200 ton Compression Load Cell
>>
CNC Machining Parts 10 Years of Processing Experience Mature and Stable Technology
>>
Gaoli Sc200/200 Double Cages Construction Elevator
>>
Vertical Machining Center High Quality Machining Body Solid Durable Automated CNC Milling Machine
>>
Ecofriendly Clear Pet Blister Plastic Blueberry Clamshell Packing Box
>>
Combination Beans Peas Cleaning Sorting Machine with Soybean Gravity Separator