Welcome to visit

Data Center 40ge/100ge Access Switch CE8855-32cq4bq-B AC Uplink Ports Network Switches Work with Cloudengine 16800 16800-X 8800

US$8,085.00
2-49 Pieces
US$6,929.00
50+ Pieces

Basic Info.

Model NO.
CE8855-32CQ4BQ-B
Transmission Rate
10/100/1000Mbps
Ports
≦8
Model Number
Cloudengine CE8855-32cq4bq-B
Dimensions (W × D ×h, mm)
43.6 mm*442 mm* 420 mm
Weight
8.31kg
Switching Capacity (Tbps)
12.8 Tbit/S
Port Description
64 X 100 Ge Qsfp28
Packet Forwarding Rate
4482 Mpps
Buffer
42 MB
Air Duct Type
Standard Front-to-Back or Back-to-Front Airflow
Data Center Interconnect (Dci)
Vxlan Mapping, Enabling Layer 2 Interconnection Be
Typical Power Consumption
378W
Maximum Power Consumption
541W
1200 W AC & 240 V DC Power Module
AC: 90-290V AC, 45-65Hz; DC: 190-290V DC
Network Virtualization
Vxlan Routing and Vxlan Bridging
Network Convergence
Fibre Channel Over Ethernet (Fcoe)
Reliability
STP, Rstp, Vbst, and Mstp
Transport Package
Strong and Fast
Specification
weight 8.31kg
Trademark
HUA WEI
Origin
Guangdong China

Product Description

Product Description
HUA WEI CloudEngine 8855 Series Data Center Switches
CE8855-32CQ4BQ Switch(32*100GE QSFP28, 4*200GE QSFP56, 2*AC Power Modules, 5*Fans, Port-side Intake)
Hua wei CloudEngine 8855 series switches are next-generation high-performance and high-density 40GE/100GE access switches designed for data centers (DCs), and provide 200GE uplink ports.
☆CloudEngine 8855 series switches have an advanced hardware structure design, and provide high-density 40GE/100GE port access and 200GE uplink ports. The switches support extensive DC features and flexible selection of the airflow direction.
☆CloudEngine 8855 series switches can work with CloudEngine 16800, 16800-X, or 8800 DC core switches to build an elastic, virtualized, high-quality, and fully-connected 200GE data center network (DCN), meeting network requirements of DCs in the cloud era.
☆CloudEngine 8855 series switches provide high-density 40GE/100GE access in DCs to build DCN platforms for enterprises and carriers in the cloud era. The switches can also work as core or aggregation switches on campus networks.
Networking Application
Typical Applications in DCs
On a typical DCN, CloudEngine 16800-X, 16800 or 8800 switches work as core switches, and CE6800 or CE8800 work as TOR switches and connect to the core switches through 40GE, 100GE, or 200GE ports to build an end-to-end and fully-connected 100GE/200GE/400GE network. The switches use VXLAN and other fabric technologies to establish a non-blocking large Layer 2 network, which allows large-scale
VM migrations and flexible service deployments.
Technical Specification
1.Hardware Specifications
Item CloudEngine 8855-32CQ4BQ
200GE QSFP56 port1 4
Switching capacity 8Tbps
Packet forwarding rate 1200 Mpps
Air duct type Standard front-to-back or back-to-front airflow
Device virtualization M-LAG
Interface Jumbo frames
Network virtualization VXLAN routing and VXLAN bridging
BGP-EVPN
SDN iMaster NCE-Fabric
Network convergence PFC and AI ECN
RDMA and RoCE (RoCE v1 and RoCE v2)
Programmability OpenFlow
OPS programming
Traffic analysis NetStream
VLAN Access, trunk, and hybrid ports
Default VLAN
Automatic MAC address learning and aging
MAC address table Static, dynamic, and blackhole MAC address entries
Source MAC address filtering
MAC address learning limiting based on ports and VLANs
IP routing IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP
IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+
IPv6 VXLAN over IPv6
IPv6 VXLAN over IPv4
IPv6 neighbor discovery (ND)
Path MTU discovery (PMTU)
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6
Multicast Multicast routing protocols such as IGMP, PIM-SM, and MSDP
IGMP snooping and IGMP proxy
IPv6 Layer 3 multicast and configuration of both Layer 2 and Layer 3 multicast services
Fast leave of multicast member interfaces
Multicast traffic suppression
Reliability LACP
STP, RSTP, VBST, and MSTP
BPDU protection
Smart link and multi-instance
Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms
VRRP, VRRP load balancing, and BFD for VRRP
BFD for BGP, IS-IS, OSPF, and static routing
BFD for VXLAN
Traffic classification based on Layer 2 headers, Layer 3 protocols, and Layer 4 protocol priorities
QoS ACL, CAR, re-marking, and scheduling
Queue scheduling modes such as PQ, DRR, and PQ+DRR
Congestion avoidance mechanisms such as WRED and tail drop
Traffic shaping
IEEE 1588v2
Intelligent O&M Network-wide path detection
Telemetry
Enhanced ERSPAN
IFIT
Packet Event: packet loss visualization and ultra-long latency visualization
Statistics collection on the buffer microburst status
VXLAN OAM: VXLAN ping and VXLAN tracert
Intelligent lossless network PFC deadlock prevention
AI ECN
ECN Overlay
Enhanced NSLB
Configuration and maintenance Terminal login through the console port, Telnet, and SSH
Network management protocols, such as SNMPv1/v2/v3
File upload and download through FTP and TFTP
Boot Read-Only Memory (BootROM) upgrade and remote online upgrade
Hot patches
User operation logs
Configuration rollback
ZTP
Security and management MACsec
Command line authority control based on user levels, preventing unauthorized users from using commands
Defense against DoS, ARP, and ICMP attacks
Port isolation, port security, and sticky MAC
Binding of the IP address, MAC address, port ID, and VLAN ID
Authentication methods, including AAA, LDAP, RADIUS, and HWTACACS
RMON
Dimensions (H x W x D) 43.6 mm × 442 mm × 420 mm
Weight in full configuration 8.31kg
Environment requirements Operating temperature: 0°C to 40°C (0 m to 1800 m) Storage temperature: -40°C to +70°C Relative humidity: 5% RH to 95% RH (noncondensing)
Operating voltage 1200 W AC & 240 V DC power module: AC: 90-290 V AC, 45-65 Hz; DC: 190-290 V DC 1200 W DC power module: -38.4 V DC to -72 V DC; +38.4V DC~+72V DC
typical power consumption 378W
Maximum power consumption 541W
Power factor 0.90 @ 15%-25% load 0.96 @ 25%-50% load 0.98 @ 50%-100% load

2.Performance and Scalability
Item Value
Maximum number of MAC address entries 640K
Maximum number of routes (FIB IPv4/IPv6) 1.5M/750K
ARP size 128K
Maximum number of VRFs 4096
IPv6 ND table size 128K
Maximum number of VRRP groups 1024
Maximum number of ECMP paths 128
Maximum number of VXLAN bridge domains 16K
Maximum number of BDIF interfaces 16K
Maximum number of virtual tunnel endpoints (VTEPs) 16K
Maximum number of LAGs 1024
Maximum number of links in a LAG 256
Maximum number of MSTIs 1000
Maximum number of VLANs where VBST can be configured 640K

3.Ordering Information
Device Description
CE8855-32CQ4BQ CE8855-32CQ4BQ Switch(32*100GE QSFP28, 4*200GE QSFP56, Without Fan and Power Modules)
CE8855-32CQ4BQ-B CE8855-32CQ4BQ Switch(32*100GE QSFP28, 4*200GE QSFP56, 2*AC Power Modules, 5*Fans, Port-side Intake)
CE8855-32CQ4BQ-F CE8855-32CQ4BQ Switch(32*100GE QSFP28, 4*200GE QSFP56, 2*AC Power Modules, 5*Fans, Port-side Exhaust)
Fan module
Model Description
FAN-031A-F Fan box (F,FAN panel side intake)
FAN-031A-B Fan box (B,FAN panel side exhaust)
FAN-031B-F Fan box (F,FAN panel side intake), supporting the electronic label function
FAN-031B-B Fan box (B,FAN panel side exhaust), supporting the electronic label function
Power module
Model Description
PAC1K2S12-PF 1200W AC&240V DC Power Module (Front to Back,Power panel side intake)
PAC1K2S12-PB 1200W AC&240V DC Power Module (Back to Front,Power panel side exhaust)
Product Display
Related Products
Company Profile
Our Advantages
The product is 100% genuine and has sufficient stock in stock;
Price discounts and fast delivery;
After sales service guarantee; Support sample and customization services.
FAQ
Q: Are you a trading company or a manufacturer? Can I use our own logo and label?
A: We are a trading company that provides domestic and international trade services. We also provide OEM/OEM services.
Q: What are the guarantees for product quality?
A: We have professional engineers who test each piece of equipment before shipment to ensure that the shipped products are in good condition.
Q: How did you resolve a defective product when I received it?
A: We have professional personnel to help you solve the problem. If the product is defective, we usually offer you a return, refund, or replacement of the defective product.
Q: What is your payment method and delivery time?
A: We accept credit cards, wire transfers, PayPal, and other payment methods. We also support fast shipping within 72 hours.
Q: What is the MOQ and how long is the warranty period?
A: The minimum order quantity for normal products is 1, and the product warranty period is usually 1 year.

>> 600MW 785nm Butterfly Fiber Coupled Laser Diode 14pin Stabilized Wavelength for Raman Spectroscopy
>> 4 Blades High Speed Ship Boat CU4 Bronze Marine Propeller
>> Eglobal Fanless Mini Router Intel Celeron J1900 4 LAN 2USB HDMI VGA 8g D3 128g SSD Mini PC
>> Fit-781d-Sm Step Motor Button Holing Sewing Machine
>> Fully Automatic Control System Wood Dry Kiln Timber Drying Chamber
>> Professional Hexagonal Wire Mesh Machine Manufacturer in China
>> Exercise Weight Lifting Outdoor PVC Waterproof Water Dumbbell Fitness Training Aqua Power Bag
>> Inflatable marine shipping salvage lifting rubber airbag
>> Disc Harrow (Medium Hydraulic Mounted Disc Harrow) 1bj Seriers
>> Grinding Machine for Kitchen Sink
>> Best Chrome-Like Mirror Effect Vacuum Metallized Pigment for Paint or Coating
>> CNC Rotor Whirling Machine for The Screw Pumps
>> Fully Automatic Double Channels Napkin Paper Serviette Folding and Cutting Machine
>> Medical Implants Grade Pure and Titanium Alloy Disc Dental Materials for Sale
>> China Manufacturer Low Price CNC Machining Lathe Machine Swiss Metal Processing Machine
>> High Quality OEM Logo Nylon + PBT Ultra Soft Bristle Plastic Manual Toothbrush Household Couple Small Head Tooth Brush
>> Ck5117cm CNC Composite Vertical Lathe Machine Tool Turning Grinding for Valve
>> MAICTOP car exterior parts headlight trim for Hilux revo 2016 chrome head light cover
>> Damping Shaft 360 ° Damping Hinge Display Screen Damping Hinge
>> frp membrane housing 4040 frp membrane shell 2540 membrane housing