Medium Voltage Underground Cable 8.7/15KV Copper Conductor XLPE/PE Insulation Armored Power Cable
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE power cable has highelectric strength, mechanical strength, high-ageing resisting, environ metal stress resisting anti-chemical cross, and it issimple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.Application
These power cable for fixed installations such as distribution networks or industrial installations. Such as Plant engineering;Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc. Product Parameters
Rated Voltage: | 6/10kV, 6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV |
Core Number: | Single Core or Three Core (1C or 3C) |
Available Dimensions: | 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2. |
Codes Available: | N2XSY, N2XSEY, NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY, N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY |
YJV, YJLV, YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32 |
Application: | For power networks, underground, outdoors and in cable ducting. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected during installation. |
Construction: | |
Conductor: | Stranded round compacted copper or aluminum conductor (Cu / Al ), copper wire annealed. |
Conductor Screen: | Semi-conducting material |
Insulation: | XLPE (Cross-Linked Polyethylene) |
Insulation Screen: | Semi-conducting material |
Metallic Screen: | Copper tape screen or copper wire screen (CTS / CWS ) |
Filler: | PP rope |
Separator: | Binding tape |
Bedding: | PVC (Polyvinyl Chloride) |
Armouring: | Single Core: Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA) |
Sheath: | PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR |
Colour: | Red or Black |
Temperature Rating: | 0°C to 90°C |
Minimum Bending Radius: | Single Core: 15 x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former) |