Welcome to visit

Rpm80m Power Meter Multi Meter Network Analyzer

US$107.00-268.00 1 Piece (MOQ)

Basic Info.

Model NO.
RPM80m
Display
Digital
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Maximum Demand Meter
Electric Equipment
Single-Phase, Two-Phase, Three-Phase
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Power Meter
Certification
RoHS, ISO, CE
Customized
Customized
Power Consumption
4vamax
Operating Voltage (Un)
85~265 VAC 50/60Hz (Depend on Order)
CT Inputs
4 Current Input: 0.05-5.5A
Voltage Inputs
4 Voltage Input : Max 690VAC (L-L)
Transport Package
Carton Box
Specification
96*96
Trademark
Romaz
Origin
China
HS Code
9030390000
Production Capacity
50000PCS/Month

Product Description

Product Description
* True RMS measurements (512 samples/cycle)
* For single-phase, two-phase, three-phase system
* Measurements:VL-L, VL-N, I, In, Cos , Pf, Hz, W, ∑W, Va, ∑Va, Var,∑Var,import Kwh, export Kwh ,import Kvarh, export Kvarh,
V-THD, I-THD,1-63th harmonic , system running hours, % voltage unbalance,% current unbalance,
% system load, total frequency
* 3 voltage and 4 current input (Measure or calculate the neutral current)
* Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
* % system load and system running hours
* Detects CT wiring errors
* Maximum, minimum and demand for U, I, P, Q, S in hours, days, months
* Real time clock with integrated backup rechargeable battery
* 4 quadrants energy measurement and monthly energy calculation
* 2 pulse output and RS485 communication: Modbus RTU
* USB port (Type C) for data transfer
* Waveforms and phase diagram for voltage, current
* Alarm event log
* Built in 64Mbit flash memory for datalog
* Data recorded in standard excel file formats for further En50160 analysis
* Comply BEC2018 in clause7.7.1-7.7.3 store data: [Voltage(L-L, L-N), Current(3P and neutral), total power factor, total energy
consumption(Kwh), maximum demand(kVA),total harmonic distortion for 3phase voltage and current] at least 3years in interval
of 15 minutes
* English, Chinese (traditional & simplied)
* Moduel function options (only one can be selected)
- 7 digital input +2 relay output(remote or alarm)(Standard)
- 7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option)
- Ethernet (Modbus TCP), Web server+2 digital input +2 relay output(remote or alarm) (option)
-LoRa wireless (Private protocol)+2 digital input+2 relay output (remote or alarm)(option)
-RS-485 interface (Modbus RTU)+2 digital input+2 relay output (remote or alarm)(option)
-WIFI wireless +2 digital input +2 relay output(remote or alarm) (option)
Product Parameters
Auxiliary Supply
Operating voltage (Un) 85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order)
Power consumption 4VA max
Measurement input
Voltage inputs for direct connection: Phase-neutral(L-N): max 400V RMS CAT III
Input impedance(for direct voltage inputs): >4MΩ
CT inputs: max 5.5A RMS
CT inputs overload capacity: max 10A
CT inputs Self-consumption : < 0.2VA
Accuracy
Three phase voltage: ± 0.2%
Currents: ± 0.2%
Powers: ± 0.5%
Powers factor: ± 0.5%
Frequency: ± 0.02%
Harmonics: ± 1%
Active energy: Class 0.5S
Reactive energy: Class 0.5S
Insulation
Insulation voltage 3kV for 1 min., 50Hz
Display
Display type 3.2inch 240x160 pix LCD
I/O
Digital inputs: Active dry contact
Digital outputs: 2 Relay N/O 220VAC 5A
Analog outputs: 4-20mADC / max load 500Ω
Pulse output: 24-30VDC Max.50mA, Min. 50msec pulse width
Memory
Recording memory: 64Mbit flash memory for Data log(USB port for download)
Communication
USB port for download datalog
Ethernet port: Auto MDIX Rj45 10/100 Base Ethernet
RS-485 port: 1 optoisolated, 4800-57600
Protocols: HTTP, HTTPS, Modbus RTU/TCP
Environmental conditions
Opterating temperature: -10···+55°C
Storage temperature: -25···+75°C
Relative humidity: 95% max without condensing
Altitude: max 2000m AMSL
Installation & use: Internal
Mechanical characteristics
Mounting: Panel mount 96x96mm(The panel cut-size 92*92mm)
Size: Front(WXH)96x96mm, Rear (HxD) 90x70mm
Degree of protection: IP40(optional IP54) on front, IP20 housing and terminals
Weight: 400g
Standard compliance
reference standard: IEC61010-1; IEC61557-1;IEC61557-12; IEC61326-1;IEC62053-21; IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30; IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2; IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6; IEC61000-4-8; IEC61000-4-11; IEC61000-4-30
Detailed Photos

Installation Instructions

Company Profile


>> Hot sale high quality Universal black exhaust tail pipe tips
>> Xhnotion Pneumatic Plastic Push to Connect Male Straight Air Hose Fittings
>> Screw Lift Emulsifying Machine Vacuum Mixing Emulsifier Homogenizer Mixer
>> NDT equipment soil compaction testing equipment
>> Zoomlion Concrete Pump Truck Zlj5350thbkf with CE ISO for Good Price
>> Loop Sensor for Boom Barrier
>> CNC Beveling Machine for H-Beams
>> Factory price amazon bestseller cast iron post mail box for outdoor garden for homes
>> Hydration Outdoor Sports Cycling Light Running Hiking Daily Race Reflective Backpack Vest
>> Stainless Steel Decorative Metal Chain Braid Ring Mesh
>> Aluminum Corner Connector Cutting Machine
>> MAICTOP AUTO PARTS halogen headlight Headlamp for hijet truck brand new
>> 1 2 3 mm Thickness Low Carbon Steel Expanded Mesh Sheet
>> Anti-Pollution Ceramic Antistatic Access Flooring for Program-Controlled Computer Rooms
>> High Efficiency 5t/H Output Orchards Feed Mill Machine for Sale
>> High-End Wc67K Hydraulic Press Brake with E21 Display Technology
>> School Classroom Furniture Movable Green White Board
>> mask making Meltblown cloth Slitting rewinder Slitter Machine
>> China Factory Digital Eco Solvent Printer Galaxy 3.2m Size I3200 4 Printer Heads
>> RF Coaxial TNC Female to N male Adapter