US$180.00-200.00
|
1 Piece
(MOQ)
|
Basic Info.
Model NO.
JTG-ZF-C34/JTGB-UF-C35Ex
Anti-Theft Alarm System-Wide
Surface Control Alarm Detectors
Infrared Sensor Probe Type
Infrared Temperature Sensor
Infrared Sensor Installation
Embedded Wall
Flame Detector
UV+IR Sensor
Certification
Sil2, Cccf, CNAS, Ukas, Mc, ILAC-MRA
Transport Package
Standard Export Packing
Production Capacity
10000 PCS/Year
Product Description
JTG-ZF-C34/JTGB-UF-C35Ex Point Type UV & IR Flame Detector Summary
JTG-ZF-C34/JTGB-UF-C35Ex point type UV & IR flame detector (hereinafter referred to detector) adopt flame multispectral signal acquisition method/full frequency wave analysis technology, it avoids the weaknesses to interference of traditional detectors. The detection environment is monitored by increasing slope signal detection technology (PAM), which improves the stability and sustainability of the detector. It ensures that the detector can quickly identify and detect fire while minimizing false alarm. The detector is suitable for all kinds of places, such as oil depot, wine depot, aircraft hangar, chemical equipment site, military equipment site, liquefied gas station, power station, tunnel, etc. With high anti-interference ability, can work well in indoor or outdoor environment.
The detector adopts six-wire connection style (two power lines, two fire touch spot lines, two fault touch spot lines), In case of alarm, the fire touch spot changes from normally open to normally closed. In case of fault alarm, the fault touch spot changes from normally closed to normally open. It can be connected with the fire alarm system of any manufactur
Technical Parameter Spectral response:190~260nm, 1.0um~1.7um. Response time:5~10s Monitoring angle:≤100° Working voltage: DC24V Static operating current: 45mA Alarm status current: 55mA Sensitivity: I class ~ class III, I class: 0-25m within the scope of the probe must be reported to the fire.
II class: 0-17 m within the scope of the probe must be reported to the fire.
III level: 0-12 m within the scope of the probe must be reported to the fire. Protection grade: IP66 Environment temperature: -10 ~ +55ºC Relative humidity: ≤93%RH(45±2ºC) Installation Angle: rotation Angle: 360°, elevation Angle: 90° Exd II CT6 Gb; Ex tD A21 IP66 T80ºC. Cable outlet thread: npt1/2 "nut explosion-proof hose is connected with outlet screw. Product size: Φ60×150mm.
Status Indicator Green: work indicator light, on when normal, internal device failure report green light does not work. Red: alarm indicator, normally off, often on fire. Power outages reset Output model Fire relay: normally open, close when alarming. Fault relay: normally closed, disconnected in case of fault Touch spot capacity: 3A /220VAC 3A /30VDC Use and Maintenance
Wiring: The wiring is shown in the picture. The red and black wires are connected to the positive and negative electrodes of the DC24V power supply. The yellow and white line is the contact output of the alarm relay, which closes when alarming. The green and blue line is the output of the fault relay, which is fault relay output, normally closed, fault disconnect. If module has terminal resistance, connect blue and green lines, yellow and white lines and terminal resistance, Resistance should be installed as close as possible to the detector. It is not recommended to install resistors near modules.
Red | DC: +24V | Connect the controller to the power supplyDC24V |
Black | DC: -24V |
White | Fire relay touch spot output, dry contact normally open, closed in case of fire. | Connect the alarm module signal end |
Yellow |
Blue | Fault relay touch spot output, dry contact normal closure, fault disconnect. | After connecting the terminal resistance in series, it is connected to the signal end of the alarm module or to the module return route in series. |
Green |
Installation Requirement Overlooking installation: Depression angle <45° Installation distance:The protection distance of detectors in oil sites is 3m ~ 5m. The protective space of chemical sites is 5m ~ 7m. The protection distance of smelting site is 7m ~ 10m. The protection spacing of power sites is 2m ~ 10m. There should be no obstacles blocking the line of sight of the detector in the fire area. If the obstacles cannot be avoided, the number of detectors should be considered to achieve no-dead Angle detection. Detector shell should be ground.
>>
R160 Multi Jet Dry Type Water Meter (NX-2)
>>
Open Mixing Mill
>>
9m Wide Disc Harrow Tractor Cultivators Agricultural Farming
>>
Natural Spray Dried Coconut Powder / Coconut Milk Powder / Coconut Juice Powder
>>
Made in China Farm Machinery Mini Skid Loader 20, 30 HP Mini Tractor Mounted 3 Discs Disc Plough, Disc Plow
>>
Africa Hot Selling Farm Tractor Tiller 1gqn-200 2m Width Rotary Tiller Cultivator for 50-75HP Tractor
>>
High quality wholesale Lacetti car Engine hood hinge R For Buick 26264352 5484205 5489367 96417505 96549000
>>
Intelligent anti-clip system electric luggage lift door foot kick sensor suitable for Mercedes Benz GLB
>>
High Quality Outdoor Wooden Cricket Kit for Kids W01d062
>>
Wholesale high quality Auto parts Regal LaCrosse Captiva car Crankshaft Torsional Damper For Chevrolet Buick 12583151 12623796
>>
48640-50070 48640-59015 Good Quality Suspension Parts Control Arm for Lexus LS460
>>
Factory Price New Design Corn Peeling/Sheller/Peeler/Shelling Machine
>>
Zy 700 High Speed Steel Pipe Tube Mill Making Machine Carbon Steel Pipe Machines Pipe Forming Machine
>>
Liquid Detergent Cosmetics Mixing Manufacturing Plant Mixing Machine
>>
High Efficiency Chicken Manure Fertilizer Chain Crusher Machine NPK Production Line
>>
Amazing Popular Steam O Belt (SOB001)
>>
Commercial Series Australian Standard Aluminum Frame Side Hinged Casement window
>>
Removal Water Cooled Handheld Laser Cleaning Machine
>>
Hot Selling High Quality Plastic Crusher Machine Recycling Blade
>>
Foldable Collapsible Retractable Telescopic Fly Fishing Landing Net Extended Fishing Landing Net