US$156.00-445.00
|
1 Piece
(MOQ)
|
Basic Info.
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Maximum Demand Meter, Power Quality Analyser
Electric Equipment
Single-Phase, Two-Phase, Three-Phase
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Certification
RoHS, ISO, CE
Operating Voltage (Un)
85~265 VAC 50/60Hz (Depend on Order)
CT Inputs
4 Current Input: 0.05-5.5A
Voltage Inputs
4 Voltage Input : Max 690VAC (L-L)
Transport Package
Carton Box
Production Capacity
50000PCS/Month
Product Description
Product Description
* True RMS measurements (1024 samples/cycle)
* Measurements:VL-L,VL-N, I, In, Cos , Pf, Hz, W, ∑W, Va, ∑Va, Var, ∑Var, import Kwh, export Kwh,import Kvarh , export Kvarh , V-THD , I-THD , 1- 128th harmonic , system running hours , % voltage unbalance , % current unbalance , % system load , total frequency , temperature &humidity(option)
* 3 voltage and 4 current input (Measure or calculate the neutral current)
* Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
* Transients detection >25us, Detection of events >10ms
* Voltage flicker measurement, % system load
* Detects CT wiring errors
* Maximum, minimum and demand for U, I, P, Q, S in hours, days, months
* Real time clock with integrated backup rechargeable battery
* 4 quadrants energy measurement. RPM95C provide 4 tariffe energy measurement and monthly energy calculation
* 2 pulse output and RS485 communication: Modbus RTU
* Waveforms capture and phase diagram for voltage, current
* Voltage and current sag/swell and transient event capture.
* Alarm event log
* USB port for data transfer
* Built in 256M flash memory for event and transient memory
* Data recorded in standard excel file formats for further EN50160 analysis
* English, Chinese (traditional & simplied)
* Moduel function options (only one can be selected)
-7 digital input +2 relay output(remote or alarm)(Standard)
-7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option)
-Ethernet (Modbus TCP), Web server+2 digital input +2 relay output(remote or alarm) (option)
-LoRa wireless (Private protocol)+2 digital input+2 relay output (remote or alarm)(option)
-RS-485 interface (Modbus RTU)+2 digital input+2 relay output (remote or alarm)(option)
-WIFI wireless+2 digital input +2 relay output(remote or alarm) (option)
Product Parameters
Auxiliary Supply |
Operating voltage (Un) | 85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order) |
Power consumption | 4VA max |
Measurement input |
Voltage inputs for direct connection: | Phase-neutral(L-N): max 400V RMS CAT III |
Input impedance(for direct voltage inputs): | >4MΩ |
CT inputs: | max 5.5A RMS |
CT inputs overload capacity: | max 10A |
CT inputs Self-consumption : | <0.2VA |
Accuracy |
Three phase voltage: | ± 0.2% |
Currents: | ± 0.2% |
Powers: | ± 0.3% |
Powers factor: | ± 0.3% |
Frequency: | ± 0.02% |
Harmonics: | Class 1 (IEC/EN61000-4-7) |
Active energy: | Class 0.2S (IEC/EN 62053-22) |
Reactive energy: | Class 0.5S (IEC/EN 62053-23) |
Insulation |
Insulation voltage | 3kV for 1 min., 50Hz |
Display |
Display type | RPM95: 3.2inch 240x160 pix, RPM95C: LCD3.5" 320x240 color TFT LCD |
I/O |
Digital inputs: | Active dry contact |
Digital outputs: | 2 Relay N/O 220VAC 5A |
Analog outputs: | 4-20mADC / max load 500Ω |
Pulse output: | 24-30VDC Max.50mA, Min. 50msec pulse width |
Memory | |
Recording memory: | max 32 GB SD (TF) |
Communication |
Ethernet port: | Auto MDIX Rj45 10/100 Base Ethernet |
RS-485 port: | 1 optoisolated, 4800-57600 |
Protocols: | HTTP, HTTPS, Modbus RTU/TCP |
Environmental conditions |
Opterating temperature: | -10···+55°C |
Storage temperature: | -25···+75°C |
Relative humidity: | 95% max without condensing |
Altitude: | max 2000m AMSL |
Installation & use: | Internal |
Mechanical characteristics |
Mounting: | Panel mount 96x96mm(The panel cut-size 92*92mm) |
Size: | Front(WXH)96x96mm, Rear (HxD) 90x70mm |
Degree of protection: | IP40(optional IP54) on front, IP20 housing and terminals |
Weight: | 400g |
Standard compliance |
reference standard: | IEC61010-1; IEC61557-1;IEC61557-12; IEC61326-1;IEC62053-21; IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30; IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2; IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6; IEC61000-4-8; IEC61000-4-11; IEC61000-4-30 |
Detailed Photos
Installation Instructions
Company Profile
>>
Customized 3 way ball valve brass stainless steel hydraulic ball valve
>>
12/24V DC Compressor 466L Solar Chest Deep Fridge Refrigerator Freezer
>>
Factory Cheap Price 14 Inch Wall Mount RJ45 Poe LCD IPS Touch Screen Panel Poe
>>
LED Spotlight / Stage Light LED PAR 64 Wall Washer Light (LED 1003)
>>
6rib 5 Folding Custom Manual Rain Sun Vinyl UV Windproof Parasol Advertising Women Gift Mini Pocket Pink Umbrella
>>
Automotive Filter Paper Corrugated Air Filter Paper for Heavy Duty
>>
R1 1sn Good Quality High Pressure Hydraulic Oil Rubber Hose
>>
One Button Easy to Operate Paint Thickness Gauge
>>
Happiness Certified Titanium Ti Composite Powder with MOQ 2 and CE Certification
>>
Travelpro Custom Magnetic Photo Frame Souvenir UV Printing MDF Fridge Magnets
>>
Taiwan 4 axis cnc machine small machining center XH7126 vertical cnc milling machine
>>
2014-2017 Sport Madly Style Wide Body Kits for Range Rover Sport body kit for Land Rover sport
>>
Ysdmill Woodworking Horizontal Style Hardwood Sawmill
>>
Saddle Stool with Contoured Seat with Foot Rest on Chrome Base
>>
Non-Woven Disposable Surgical Cap Manufacturing Machine Hospital Surgical Cap Ultrasonic Automatic Manufacturing Machine
>>
Hydraulic Travelling Head Gloves Cutting Hans Press Machine
>>
CNC Lathe Manufacturer You Can Trust
>>
Portable Steel Nail Roadblock Barrier (LZ-06)
>>
ABB PFTL201C 10KN 3BSE007913R0010 Module card parts inventory
>>
FTTH Mini Wdm Optical Node Receiver for CATV and Pon FTTH Solution