| Technical specifications |
| General |
| UPS output power rating (1.0 p.f.) | 25,50,75,100,125,150,175,200kW |
| Efficiency in double conversion mode | >96% |
| Efficiency in Energy Saver System (ESS) | >99% |
| Static bypass rating | 200kW |
| External paralleling | up to 4 units with HotSync technology |
| UPS topology | Double conversion |
| UPS degree of protection | IP20 |
| Acoustic noise at 1 m,in 25 ºC ambient temperature | <70 dBA in double conversion,<55 dBA in ESS |
| Altitude (max) | 1000m above sea level at 40 ºC.Maximum 2000m with 1%derating per each add.100 m |
| Input |
| Rated input voltage | 220/380 V,230/400 V,240/415V 50/60 Hz |
| Voltage tolerance -Rectifier input | 187 to 276V |
| Voltage tolerance -Bypass input | Rated voltage -15%/+10% |
| Rated input frequency | 50 or 60 Hz,user configurable |
| Frequency tolerance | 40 to 72 Hz |
| Input wiring | 3 phase+neutral |
| Input power factor at 100%load | >0.99 |
| Input ITHD | <3% |
| Rated input r.m.s current | 25kW | 50kW | 75kW | 100kW | 125kW | 150kW | 175kW | 200kW |
| 380V | 40A | 80 A | 120A | 159 A | 199 A | 239A | 278 A | 318 A |
| 400V | 38A | 76A | 114 A | 51 A | 189 A | 227 A | 264 A | 302 A |
| 415V | 37 A | 73 A | 110 A | 46 A | 182 A | 219 A | 255 A | 291 A |
| Soft start capability | Yes |
| Intemal backfeed protection | Yes |
| Output |
| Output wiring | 3 phase +neutral |
| Rated output voltage rating | 220/380 V,230/400 V,240/415 V.configurable |
| Total voltage harmonic distortion | <1%(100%linear load);<3%(100%non-linear load) |
| Output power factor | 1.0 |
| Permitted load power factor | 0.8 lagging to 0.8 leading |
| Overload on inverter | 10 min 102-110%,60 sec 111-125%,10 sec 126-150%,300 ms>150% |
| Overload on bypass | Continuous<125%,20 ms 1000% |
| Battery |
| Battery type | 12V,VRLA |
| Charging method | ABM technology or Float |
| Temperature compensation | Optional |
| Battery nominal voltage (VRLA) | 480V |
| Battery quantity | 36 to 44 blocks.Default is 40 blocks |
| Charge current limit | Default 5A,configurable maximum 25A per UPM |
| Battery start capability | Yes |
| Communications |
| Minislot | 3 communication bays |
| Network/SNMP interface | Yes,optional |
| Serial ports | Built-in host and device USB |
| Standard connectivity ports | Mini-slot ports for optional cards,Device USB and Host USB,RS-232 service port,relay output, 5 building alarm inputs and a dedicated EPO |
| Accessorles | MiniSlot connectivity (Web/SNMP,ModBus/Jbus,Relay) |
| External Battery Cabinet(EBC) |
| Parallel Tie Cabinet(PTC) |
| External Maintenance Bypass Switches(EMBS) |
| External Battery Cabinet Breaker(EBCB) |
| Compliance with standards |
| Safety | IFC 62040-1 |
| EMC | EC 62040-2 |
| Performance | EC 62040-3 |
1. May I take some samples to test before I placing the order?
Yes, we can offer sample testing for you to verify product quality and performance.
2. What is the warranty?
We support 1 years warranty.
Eaton, Vertiv, APC, Santak, Vesion & OEM/ODM UPS; Cooling, MDC, PDU and so on.
4. What payment methods does your conmpany support?
We could accept T/T, credit card, Alipay or L/C at sight.
5. What are the terms can you offer for us?
We could offer EXW, FOB, CIF, DDP and so on.