Welcome to visit

DC Wall-Mounted Electric Storage 60L 80L Household Solar PV Water Heater

US$276.00-1,685.00 1 Piece (MOQ)

Basic Info.

Model NO.
Household Solar PV Water Heater
Max. Capacity
>200L
Structure
Separate Type
Pressure
PV Panel
Interior Material
Stainless Steel
Collector Components
Heating Tube
Composition
Collector
Certification
CE, CB
The Tank Capacity (L)
50-300
The Tank Material
Enamel
PV Peak Voltage (Vpmax)
DC( 1-150V)
PV Open Circuit Voltage (Vop)
84V-126V
PV Peak Power (W)
500-2000W
Transport Package
Carton Box
Specification
50L 100L 150L 200L 300L
Trademark
Solargreen
Origin
Zhejiang
HS Code
84191990
Production Capacity
5000PCS Per Month

Packaging & Delivery

Package Size
600.00cm * 500.00cm * 900.00cm
Package Gross Weight
25.000kg

Product Description


DC Wall-mounted Electric Storage 60L 80L Household Solar PV Water Heater
Solar water heater features:
(1) Large screen temperature indication with heating indicator light, working status at a glance.
(2) Microcomputer control, heating and insulation automatic control.
(3) The inner liner is made of high-quality steel plate and equipped with a liner protection device, which is anti-corrosion and pressure-resistant and durable.
(4) It has multiple safety protection functions such as leakage protection, anti-dry protection, over- temperature protection, over-pressure protection, and leakage warning.
(5) The insulation layer is foamed with thickened polyurethane, which has good heat preservation effect and saves energy.
(6) It has a wide range of water pressure and large capacity, and can be used for water at the same time.
Solar water heater specification:
Type GF-50LII(PV)(DC Only) GF-60LII(PV)(DC Only) GF-80LII(PV)(DC Only) GF-50L(PV)(ACDC) GF-60L(PV)(ACDC) GF-80L(PV)(ACDC) GF-100L(PV)(ACDC) GF-200L(PV)(ACDC)
The tank capacity (L) 50 60 80 50 60 80 100 200
The tank material enamel enamel enamel enamel enamel enamel enamel enamel
PV peak voltage (Vpmax) DC( 1-150V) DC( 1-150V) DC( 1-150V) DC( 1-150V) DC( 1-150V) DC( 1-150V) DC( 1-150V) DC( 1-150V)*2
PV open circuit voltage (Vop) 84 84 126 84 84 126 126 126*2
PV peak power (W) 500w or above 500w or above 800w or above 500w or above 500w or above 800w or above 800w or above 2000w or above
Grid Power (V) 220-240V 220-240V 220-240V 220-240V 220-240V
Power frequency (Hz) 50 50 50 50 50
Rated power consumption W/H 2000 2000 2000 2000 2000*2
(MPa)Nominal pressure (Mpa) 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
AC.Temperature range (ºC) 30--75 30--75 30--75 30--75 30--75
DC.Temperature range (ºC) ≥75ºCOFF/≤65ºCON
The extermal diameter (mm) 390 390 470 390 390 470 470 520
Outer barrel length(mm) 695 900 780 785 900 780 915 1520
Insulation thickness (mm) 25 25 25 35 35 35 35 25
Insulation density (Kg/m³) 34 34 34 34 34 34 34 34
Insulation material Environmentally friendly polyurethane
24hε) Natural energy consumption coefficient (ε) 0.7 0.7 0.7 0.58 0.58 0.58 0.58 0.7
Energy consumption level Super grade2 Super grade 2 Super grade 2 Super grade 1 Super grade 1 Super grade 1 Super grade 1 Super grade 2
Hot water output(μ) 80.00% 80.00% 80.00% 80.00% 80.00% 80.00% 80.00% 80.00%
Energy efficiency Super grade2 Super grade2 Super grade2 Super grade 1 Super grade 1 Super grade 1 Super grade 1 Super grade 1

Product Details:
Special warning:
1. This electric water heater must have a safe and reliable grounding device.
2. This machine must be installed with a safety valve at the water inlet.
3, must be filled with water before powering up, when adding water should open the water inlet and outlet simultaneously,after fill up the water,it will flow out from the water outlet.
4. The water inlet and outlet of the water heater cannot be closed at the sametime.
5. It should be cleaned once for half a year.
Method: first close the tap water valve, then unscrew the drain port (be careful to avoid hot water) and then open the water outlet valve, the water in the machine will flow out from the drain outlet. After emptying, open the tap water valve and rinse it several times until the water that flows out is free of impurities.
Daily mainternance:
1, Always pay attention to the pipe joints with or without water leakage, if any, timely treatment.
2. Regularly (one week) check whether the leakage test plug of the leakage protection plug power cord "test power off " button can be operated.
3. Always observe whether the safety valve can be properly relieved.
4. Always check if the grounding of the power socket is firm and meet the power supply requirements.
5, Rigorous wethand plugged in the power plug, the power plug should be unplugged when not in use for a long time.
6. Due to the different water quality and hardness of different areas, the water heater should be drained regularly to discharge the sediment at the bottom of the tank. To empty the water heater, first close the tap water valve, then unscrew the drain port (be careful to avoid hot water), then open the water outlet valve, the water in the machine will flow out from the drain outlet. After emptying, open the tap water valve and rinse it several times until the water that flows out is free of impurities.
7. The safety valve should not be replaced at will. Only the original parts can be used. The pressure of the safety valve should not be adjusted by itself. At least once a month, the safety valve handle is swayed (unscrew the fixing screw before shaking) to see if there is water Discharge, if it can not be discharged, notify the manufacturer or the manufacturer of the service point to repair.
Common fault and approach:
Fault
phenomenon
Cause Analysis Approach

Water discharging is cold water
(The work indicator is off)
1. The reset button on the plug or the power switch is not pressed
2. Power fuse off or air switch jump
or leakage protection switch action
3. Power supply line blackout
4. Poor contact in the power outlet 5. The lowest temperature control state of the thermostat
6. Thermostat, thermal circuit
breaker is bad
1. Press thereset button or power switch
2. Replace the fuse (close the air switch), reset the leakage protection switch
3. Power supply to be powered
4. Replace the power outlet
5. Adjust the thermostat to the "high temperature" file
6. Replace the thermostat, thermal circuit breaker

Water is cold water
(The work indicator is on)
1. Heating time is not enough
2. Electric heating tube burned out
3. Mixing valve failure
The patch cord is loose and the contact is poor.
Waiting for heating
2. Replace the electric heating tube
3. Replace the mixing valve
Replacement connector

Hot water outlet does not produce water
1. Tap water to stop water
2. The water pressure is too low
3. The tap water inlet valve is not open
4. Mixing valve failure
Inlet and outlet pipe failure
1. Waiting for tap water supply
2. Re-use when the water pressure rises
3. Open the inlet valve
4. Replace the mixing valve
5. Check the replacement of the inlet and outlet pipe
Remaining current protector reset button cannot be reset
Leakage
2. Plug damage
1. Check for leakage faults: power cord, internal connection line, thermostat, over-temperature protector, electric heating tube, etc.
2. Replace the plug or professional repair

Warning light on
1. Ground wire is charged
2. Machine leakage
Stop using, notify the professional to repair

Fault code table
E2 dry burning protection
E3 temperature sensor failure
E4 over temperature protection
Power off after adding water
Replace the temperature sensor
Replace the board

More hot items:

>> modern design bedroom upvc casement doors interior pvc swing door
>> Fashion Skinny Plain Color Conference Tie Polyester Silk Men Necktie for Formal Negotiation
>> Mica Powder Chameleon Mirror Effect Silver/Golden/Red/Green Pearl Pigment
>> Book Cover Kraft Paper Corner Rounded Machine Edge Binding Machine Corner Rounding
>> Industrial Computerized Socks Making Machine
>> High Speed Plastic Mixer Unit Internal Mixing Machine
>> High Quality and Cheap Price Fresh Potatoes From China
>> Self Propel Hand Held Corn Harvesters /Mini Maize Combine Harvester Machine Small Farm Potato Harvester
>> Steel Bar Making Machine Manufacturer From China with Export Rights
>> Heavy Duty 14-50P To 14-50R Plug Receptacle Connector With Grip Handle 6AWG3C+8AWG1C 50 Amp 36 Feet RV Power Extension Cord
>> Custom Logo Wholesale Emergency Thermal Blankets, Survival Reflective Thermal First Aid Foil Blanket
>> Advanced Soya Soybean Extruder Machines for Poultry Animal Feed
>> C6246 460mm China manual Metal lathe machine price for precision metal cutting
>> Amsamotion 200PLC CPU224XP Compatible Siemens S7-200 6es7 214-2ad23-0xb8 214-2bd23-0xb8
>> Stainless Steel Milk Juice Storage Tank for Beverage Factory Price
>> Qt4-15 Hydraulic Automatic Block Production Line Concrete Block Making Machine Many Types Block Machine
>> Premium Comfortable Theatre Chair for Auditoriums and Events
>> Building Material Board Terrace WPC Economic Outdoor Flooring Decking
>> Automatic Disposable Plastic Glove Making Machine HDPE PE Production Line
>> Dimond Multi-Wire Saw Cutting Machine CF680h for Magnets Quartz Crystal Processing Tool