US$1,000.00-4,000.00
|
1 Piece
(MOQ)
|
Basic Info.
Production Capacity
1000PCS/Month
Product Description
System DescriptionThe UHS14 System utilizes ultrasonic energy to enable haemostatic cutting and/or coagulation of soft tissue. The system consists of an ultrasonic generator, a foot switch, an optional hand switching adaptor, a hand piece, and a variety of open and minimally invasive instruments.
Hand Piece Scalpel ENDOHP36/ENDOHP23/ENDOHP14
Foot Switch ENDOFS00
Ultrasonic Scalpel System UHE14
The instruments vibrate longitudinally at 55.5 kilohertz. This ultrasonic vibration at the blade enhances its cutting ability. The same vibration seals small vessels with coagulated blood and tissue proteins. Haemostasis occurs when tissue couples with the instrument. This coupling causes collagen molecules within the tissue to vibrate and become denatured, forming a coagulum.
Transducer ENDOT55.5
Indications
The UHS14 System is indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The System instruments can be used as an adjunct to or substitute for electro surgery, lasers, and steel scalpels. Contraindications The instruments are not indicated for incising bone.
The instruments are not intended for contraceptive tubal occlusion. System ComponentsGenerator
The generator supplies the hand piece with electrical energy and facilitates selection of power levels, system monitoring, and system diagnostics.
Power is delivered by activating the foot switch or hand switching adaptor.
Hand Piece
The hand piece contains an acoustic transducer that converts the electrical energy supplied by the generator to mechanical motion. The transducer is connected to an ultrasonic wave guide/amplifier which amplifies the motion produced by the transducer and relays it to the instrument.
Instrument
The mechanical motion from the hand piece advances to the instrument, transmitting ultrasonic energy which enables
haemostatic cutting and/or coagulation of tissue. Power LevelsThe generator delivers two power levels: minimum (MIN) and maximum (MAX). The minimum power level may be adjusted by the user from Level 1 to 5. The maximum power level is always Level 5. With all instruments except the ball coagulator, use a higher generator power level for greater tissue cutting speed and a lower generator power level for greater coagulation. For the ball coagulator, higher generator power levels will provide greater coagulation. The amount of energy delivered to the tissue and resultant tissue effects are a function of many factors including the power level selected, instrument characteristics, grip force (when applicable), tissue tension, tissue type, pathology, and surgical technique.
Appendix: Our Ultrasonic Scalpel UHS14 compared with J&J,Accessories compatible
Name | HYCD300 | J&J GEN300 | J&J GN11 |
Input voltage | AC90-240V | AC90-240V | AC90-240V |
Operating temperature | 10-30° | 10-30° | 10-30° |
Driver frequency | 55.5kHz | 55.5kHz | 55.5kHz |
Scalpel vibration | 50-100um | 50-100um | 50-100um |
Ultrasonic transducer | HPT55.5S,HPT55.5B | | |
| HP054,HPBLUE | HP054,HPBLUE | HP054,HPBLUE |
Ultrasonic hand piece scalpel | HPS36P,HPS23P,etc | HPS36P,HPS23P,etc | |
| ACE36E,ACE23E,etc | ACE36E,ACE23E,etc | |
| HAR36,HAR23 | | HAR36,HAR23 |
| HPS9B(FOCUS) | HPS9B(FOCUS) | |
| PCS9(FOCUS) | PCS9(FOCUS) | PCS9(FOCUS) |
Use of the hand piece scalpel | Hit a hard object without damage | Hit a hard object will be damaged | Hit a hard object will be damaged |
| Can closure 5mm Vascular | Can closure 5mm Vascular | Can closure 5mm Vascular |
| Hemostatic cutting fast | Hemostatic cutting fast | Hemostatic cutting fast |
Disinfection of the hand piece scalpel | Support 134°C sterilization | Not support 134°C sterilization | Not support 134°C sterilization |
| Reuse | Disposable products | Disposable products |
Pedal | FSW01 | FSW01 | -- |
Generator | Self-test | Self-test | Self-test |
| Fault Display | Fault Display | Fault Display |
| Working Voice | Working Voice | Working Voice |
| Sound Failure | Sound Failure | Sound Failure |
Applicable scope | For laparoscopic surgery For open surgery For superficial surgery | For laparoscopic surgery For open surgery For superficial surgery | For laparoscopic surgery For open surgery For superficial surgery |
Not Applicable | Bone cutting and tubal closure | Bone cutting and tubal closure | Bone cutting and tubal closure |
>>
RoHS Compliant Eco-Friendly Ec Brushless AC Cooling Motors for Fan
>>
for Sylphy 2014-12 Sentra 2014-13 Power Window Regulator Lifter W/ Motor 80701-3ra0a A01,807213sg0a, 807219am0a FL (6 pins) Supplier Czz Auto Parts Manufacturer
>>
Fusinda New Power Weeder / Power Tiller / Mini Tiller with ATV Tires
>>
3-pc 1000psi BSPT ISO 5211 DIRECT MOUNTING PAD CF8M BALL VALVE
>>
3 Head Computer Embroidery Machine Top Quality Embroidery Machine
>>
Giraffe - 3D Puzzle Eco-Friendly Paper Crafts DIY STEM Toys Educational Learning 3D Puzzles for Kids 7+ Perfect Gifts for All
>>
Factory made healthcare high potential therapy device to treat insomnia headache
>>
Scrap Car Truck Tire Bumper Tyre Shredder Rubber Product Recycling Machinery
>>
CE Certification Continuous Handheld Laser Cleaning Machine
>>
TM-8812 UT Thickness Gauge Digital Electronic Thickness Gauge
>>
Make More Money Fish Food Making Tamil 200kg/H 500kg/H 800kg/H 1000kg/H 1500kg/H 2500kg/H 3500kg/H with Twin Screw Extruder
>>
Galvanized Steel Resistant Anti Slip Grip Strut Grating
>>
Chinese Factory 304 2b Cr Stainless Steel Coil on Sale
>>
CR2050 button battery is suitable for all kinds of electronic products
>>
Complete Rice husk sawdust straw fuel wood pellets making machine line
>>
Used Cat Excavator 320d2 Caterpillar Original Equipment Tracked Digger Secondhand 20t Machine
>>
Factory Custom Garden Decoration Pure White Stone Marble Sitting Buddha Statue for Wholesale
>>
Advanced Technology Full Servo Menstrual Pants Production Line
>>
Zkx750d CNC Milling Machine Center with Drilling Spindle
>>
Hand Cream Tube Empty Aluminum Cosmetic Packaging Abl Tube with Cap