* Selecting Temperature Sensor PT1000 To Achieve Thermal Energy Measurement Function
* Suitable For DN20-DN6000 Flow Measurement By Selecting Different Size Transducers
Measuring Principle
| Transit-time
|
Velocity
| 0.01 - 12 m/s, Bi-directional Measurement
|
Resolution
| 0.25mm/s
|
Repeatability
| 0.1%
|
Accuracy
| ±1.0% R
|
Response Time
| 0.5s
|
Sensitivity
| 0.003m/s
|
Damping
| 0-99s(settable by user )
|
Suitable Fluid
| Clean or tiny amounts of solids, air bubbles liquid , Turbidity<10000 ppm
|
Power Supply
| AC: 85-265V DC:12- 36V/500mA
|
Installation
| Wall Mounted
|
Protection Class
| IP66
|
Operating Temperature
| -40℃ to +75℃
|
Enclosure Material
| Fiberglass
|
Display
| 4X8 Chinese Or 4X16 English,Backlit
|
Measuring Unit
| meter,ft,m³,liter,ft³,gallon,barrel etc.
|
Communication Output
| 4~20mA, OCT, Relay, RS485 (Modbus-RUT), Data Logger ,GPRS
|
Energy Unit
| Unit : GJ,Opt: KWh
|
Security
| Keypad Lockout, System Lockout
|
Size
| 244*196*114mm
|
Weight
| 2.4kg
|