US$2,203.95-2,810.01 | 1 Piece (MOQ) |
Description | CE6881-48S6CQ switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side intake) | |
Part Number | 02352QGF 02352QGF-001 02352QGF-003 02352QGF-004 02352QGF-006 02352QGF-007 | |
Model | CE6881-48s6cq | |
First supported version | V200R005C20 |
Detailed Photos | |
Dimensions with packaging (H x W x D) [mm (in.)] | 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.1 mm (1.72 in. x 17.40 in. x 17.56 in.) |
Weight without packaging [kg (lb)] | 5.7 kg (12.57 lb) (excluding optical modules, power modules, and fan modules) |
Weight without packaging (full configuration) [kg (lb)] | 7.8 kg (17.2 lb) (including AC power modules and fan modules but excluding optical modules. If the device supports multiple models of modules, the heaviest modules are used for the measurement.) |
Installation Type | Cabinet installation |
CPU | Quad-core, 1.4 GHz |
Memory | DRAM: 4 GB |
NOR Flash | 64 MB |
NAND Flash | 4 GB |
USB | Supported |
Power supply mode | AC DC HVDC |
Console port | RJ45 |
Downlink Service interface | 48*10GE SFP+ NOTE: 1. 10GE ports can be configured to work at 1 Gbit/s. Ports 13-16 and 25-28 can be configured to work at 10 Gbit/s or 1 Gbit/s using commands, and the speed of other ports can be auto-negotiated based on optical modules. (In V200R005C20, ports 13-16 and 25-28 cannot be configured to work at 1 Gbit/s. In V200R019C10 and later versions, they can be configured to work at 1 Gbit/s.) 2. 10GE LRM/80 km linear optical modules are not supported. 3. 10GE 1 m/3 m/5 m copper cables are supported. |
Uplink Service interface | 6*100GE QSFP28 NOTE: 1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. 2. In V200R022C00 and earlier versions, 100GE ports cannot be split. In V200R022C10, ports 5 and 6 can be split into 4 x 25GE or 4 x 10GE ports. Other ports cannot be split. 40GE/100GE port 5 supports only static split, and 40GE/100GE port 4 is deleted after split is configured. After split is canceled for 40GE/100GE port 5, 40GE/100GE port 5 can be restored, but 40GE/100GE port 4 can be restored only after the card is restarted. After a port is split, the port cannot be connected using a copper cable. When a copper cable is installed on the port, a message is displayed, indicating that the medium does not match. 3. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on stack ports and M-LAG peer-link ports. 100G 3/5 m copper cables support only RS FEC. After the non-RS FEC mode is configured, the port enters the error-down state. |
Service port supporting the stack function | 10GE and 100GE optical ports |
RTC | Supported |
Typical power consumption [W] | 194 W (100% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules) 240 W (100% throughput, short-distance optical modules on all ports, dual power modules) |
Typical heat dissipation [BTU/hour] | 662 BTU/hour (100% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules) 819 BTU/hour (100% throughput, short-distance optical modules on all ports, dual power modules) |
Static power consumption [W] | 161 W |
Static heat dissipation [BTU/hour] | 549 BTU/hour |
Maximum power consumption [W] | 349 W |
Maximum heat dissipation | 1191 |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC 1000 W DC power module: -48 V DC to -60 V DC 1200 W high-voltage DC power module: 240 V DC to 380 V DC |
Input voltage range [V] | 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC 1000 W DC power module: -38.4 V DC to -72 V DC 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A] | 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) 1000 W DC power module: 30 A (-48 V DC to -60 V DC) 1200 W high-voltage DC power module: 8 A |
Rated output power [W] | 600 W AC&240 V DC power module: 600 W 1000 W DC power module: 1000 W 1200 W high-voltage DC power module: 1200 W |
Certification | Compliance with safety standards Compliance with EMC standards Compliance with environment and environmental protection standards |
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Redundant fans | Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short period of time. However, you are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Front-to-back or back-to-front airflow, depending on the selected fan modules and power modules |
Availability | 0.9999960856 |
MTBF [year] | 45.9 years |
MTTR [hour] | 1.57 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: < 58 dB(A) Back-to-front airflow: < 57 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: < 75 dB(A) Back-to-front airflow: < 74 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | < 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Item | CloudEngine 6881-48S6CQ |
Device virtualization | iStack |
M-LAG | |
Network virtualization | VXLAN |
BGP-EVPN | |
QinQ access VXLAN | |
Data center interconnect | VXLAN mapping, implementing interconnection between multiple DCI networks at Layer 2 |
SDN | iMaster NCE-Fabric |
Network convergence | PFC and ECN |
RDMA and RoCE (RoCE v1 and RoCE v2) | |
Programmability | OPS programming |
Ansible-based automatic configuration and open-source module release | |
Traffic analysis | NetStream |
sFlow | |
VLAN | Adding access, trunk, and hybrid interfaces to VLANs |
Default VLAN | |
QinQ | |
MAC address | Dynamic learning and aging of MAC address entries |
Static, dynamic, and blackhole MAC address entries | |
Packet filtering based on source MAC addresses | |
MAC address limiting based on ports and VLANs | |
IP routing | IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP |
IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
IP packet fragmentation and reassembly | |
IPv6 | VXLAN over IPv6 |
IPv6 VXLAN over IPv4 | |
IPv6 Neighbor Discovery (ND) | |
Path MTU Discovery (PMTU) | |
TCP6, IPv6 ping, IPv6 tracert, IPv6 socket , UDP6, and Raw IP6 | |
Multicast | Multicast routing protocols such as IGMP, PIM-SM, and MBGP |
IGMP snooping | |
IGMP proxy | |
Fast leaving of multicast member interfaces | |
Multicast traffic suppression | |
Multicast VLAN | |
Reliability | Fine-grained microsegmentation isolation |
Link Aggregation Control Protocol (LACP) | |
STP, RSTP, VBST, and MSTP | |
BPDU Guard | |
Smart Link and multi-instance | |
Device Link Detection Protocol (DLDP) | |
Hardware-based Bidirectional Forwarding Detection (BFD) | |
VRRP, VRRP load balancing, and BFD for VRRP | |
BFD for BGP/IS-IS/OSPF/Static route | |
BFD for VXLAN | |
QoS | Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information |
ACL, CAR, re-marking, and scheduling | |
Queue scheduling modes such as PQ,DRR and PQ+DRR | |
Congestion avoidance mechanisms, including WRED and tail drop | |
Traffic shaping | |
O&M | iPCA (Packet Conservation Algorithm for Internet) |
Network-wide path detection | |
Telemetry | |
ERSPAN+ | |
Statistics on the buffer microburst status | |
VXLAN OAM: VXLAN ping and VXLAN tracert | |
Configuration and maintenance | Console, Telnet, and SSH terminals |
Network management protocols, such as SNMPv1/v2/v3 | |
File upload and download through FTP and TFTP | |
BootROM upgrade and remote upgrade | |
Hot patches | |
User operation logs | |
Zero Touch Provisioning (ZTP) | |
Security and management | Command line authority control based on user levels, preventing unauthorized users from using commands |
Defense against DoS address attacks, ARP storms, and ICMP attacks | |
Port isolation, port security, and sticky MAC | |
Binding of the IP address, MAC address, port number, and VLAN ID | |
Authentication methods, including AAA, RADIUS, and HWTACACS | |
Remote Network Monitoring (RMON) |
Mainframe | |
CE6881-48S6CQ | CE6881-48S6CQ switch (48*10G SFP+, 6*100G QSFP28, without fan and power modules) |
CE6881-48S6CQ-B | CE6881-48S6CQ-B switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side intake) |
CE6881-48S6CQ-F | CE6881-48S6CQ-F switch (48*10G SFP+, 6*100G QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust) |
CE6881-48T6CQ | CE6881-48T6CQ switch (48*10G RJ45, 6*100G QSFP28, without fan and power modules) |
FAN-031A-F | Fan box (F,FAN panel side intake) |
FAN-031A-B | Fan box (B,FAN panel side exhaust) |
PAC600S12-CF | 600W AC Power Module(Front to |
Back,Power panel side intake) | |
PAC600S12-CB | 600W AC Power Module(Back to Front, |
Power panel side exhaust) | |
PDC1000S12-DF | 1000W DC Power Module (Front to |
Back,Power panel side intake) | |
PDC1000S12-DB | 1000W DC Power Module (Front to |
Back,Power panel side exhaust) | |
PHD1K2S12-DB | 1200W HVDC Power Module (Back to |
Front, Power panel side exhaust) | |
N1-CE68LIC-CFMM | N1-CloudFabric Management SW License for CloudEngine 6800 |
N1-CE68CFMM-SnS1Y | N1-CE68CFMM-SnS1Y,N1-CloudFabric Management SW License for CloudEngine 6800 |
N1-CE68LIC-CFFD | N1-CloudFabric Foundation SW License for CloudEngine 6800 |
N1-CE68CFFD-SnS1Y | N1-CloudFabric Foundation SW License for CloudEngine 6800-SnS-Year |
N1-CE68LIC-CFAD | N1-CloudFabric Advanced SW License for CloudEngine 6800 |
N1-CE68CFAD-SnS1Y | N1-CloudFabric Advanced SW License for CloudEngine -SnS -Year |
N1-CE68LIC-CFPM | N1-CloudFabric Premium SW License for CloudEngine 6800 |
N1-CE68CFPM-SnS1Y | N1-CloudFabric Premium SW License for CloudEngine 6800 -SnS-Year |
Packing: 1. Original Carton Package. 2. As your requirement. | |
Delivery: 1. 3-7 Working days after received the payment. 2. Shipment: Sea transportation & Air transportation ( DHL / UPS / TNT / FedEx / EMS ) | |