1-32 zone conventional fire detection control panel
Introduction:
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Parameters:
ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
Power specification | |
Mains supply voltage | 110VAC or 240VAC |
Internal power supply | 27.2VDC |
Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes |
Battery protection for low voltage | Yes |
Batteries (default configuration) | 12V2AH*2 |
Detector circuit specification | |
Number of circuit | 1 | 2 | 4-16 | 4-32 |
Line fault monitor for open circuit | Yes |
Line fault monitor for short circuit | Yes |
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor |
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) |
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) |
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt |
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. |
Maximum number of manual call points per zone | No limit |
Sounder circuit specification | |
Number of general circuits | 2 |
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) |
Line fault monitor for open circuit | Yes |
Line fault monitor for short circuit | Yes |
Outputs fused AT | 400mA |
Maximum number of bells @ 20mA of each sounder output | 20 |
Fuses | |
Battery fuse | 1.5A F 20mm |
Sounder outputs | 500mA F 20mm |
Fire and fault output | |
Output type | NC and NO relay |
Maximum current | 100mA |
Connection block | |
Largest acceptable conductor size | 2.5mm2 |
Smallest acceptable conductor size | 0.75mm2 |
Size and weight | | |
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Show board for conventional fire alarm system
Company
Contact us
Swing Cao
>>
Various types of American windows single hung double hung window low U-factor pvc windows aluminum windows
>>
up Traction Rotary ABC Three Layer Co Extrusion Film Blowing Machine
>>
Woodworking CNC Router Atc CNC 1325 Atc Woodworking Machine for Furniture
>>
Children′s Variety of Fun Intellectual Development Wooden Puzzles
>>
1 Year Block Stacker Cement Cuber System Concrete Brick Machine OEM
>>
Contemporary Custom Copper Chandelier with Unique Design Features
>>
Suitable Size Tractor Ta254 Series Wheeled Tractor Ta254-A9
>>
Fiberglass Reinforced Plastic Rod for Industrial Use D=4mm
>>
Factory price nougat cooker electric gas pot mixer for sugar candy
>>
Factory Price 50W 60W 75W IP20 3years Warranty LED Panel pendant Light for Offices Hotel
>>
Backlit Light Guide Plate 18X24 LED Slim Picture Movie Poster Advertising Light Box
>>
Wenovus Wn-G25 Multi-Function Agricultural Machine Diesel Powered Crawler Rotary Tiller Tractor 25HP 1247cc Agricultural Crawler Tiller Dry Land
>>
Competitive V3f Buildingeyes Elevator CE Guarantee (BEC06)
>>
Rice Harvester 4lz-5.0 4lz-6.0
>>
LINGKE high quality 15kHz 2600w usb card sockets pp ultrasonic plastic welding machine
>>
Iei Imba-H420 ATX Industrial Motherboard Dual-Channel DDR4
>>
Hoosun Advanced Air Classifier & Grinder for Chemical and Powder Processing
>>
Gamemax RGB 850W Gaming PSU, Rtx3090, Computer Power Supply, PC Gaming, Gamer
>>
Self-Propelled Cattle Feed Mixer Dairy Farm Horizontal Vertical Tmr Feed Crusher Mixer
>>
PEEK Plate Bar PEEK Plastic Polyether Ether Ketone